Calpeda pressure booster pump NGXM 6/18 100l GWS horizontal 230V 0,33-0,46MPa

Technical Specifications

Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
9,20
Power output - P2 [kW]
1,50

Show all Tech Specs

Goods cannot be purchased online. These are either oversized goods with an individual price of transport or an assortment that can only be purchased on demand. If you are interested in the goods, contact us at 800 100 763 or email [email protected]

800.92 VAT included

Not sellable online

Register your business and get the benefits of a user account. %

Brand:
CALPEDA
Product No.:
ZB00061518
Sale group:
CECK
EAN:
8596455020769

Product variants

  • Technical Specifications
  • Product No.
  • Pump design
  • Drinking water certificate
  • Automatic thermal protection
  • Maximum current [A]
  • Power output - P2 [kW]
  • Capacitor
  • Construction
  • Maximum flow [l/min]
  • Maximum head [m]
  • Impeller material
  • Vessel volume [l]
  • Dry run protection
  • Speed ​​control
  • Suction port ["]
  • Maximum suction lift [m]
  • Protection [IP]
  • Off switch
  • Input voltage [V]
  • Stop pressure [bar]
  • Delivery port ["]
  • Start pressure [bar]
  • Availability
  • Price

next

Variant Product No.

Availability

Price (VAT incl.)

Pump design
horizontal
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
4,50
Power output - P2 [kW]
0,55
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
53,30
Maximum head [m]
46,80
Impeller material
noryl
Vessel volume [l]
24
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
9
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
2,8
Delivery port ["]
1
Start pressure [bar]
1,4
Pump design
horizontal
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
4,50
Power output - P2 [kW]
0,65
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
60
Maximum head [m]
50
Impeller material
noryl
Vessel volume [l]
24
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
9
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
3,5
Delivery port ["]
1
Start pressure [bar]
2,1
Pump design
horizontal
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
4,50
Power output - P2 [kW]
0,65
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
60
Maximum head [m]
50
Impeller material
noryl
Vessel volume [l]
35
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
9
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
3,5
Delivery port ["]
1
Start pressure [bar]
2,1
Pump design
horizontal
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
4,50
Power output - P2 [kW]
0,65
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
60
Maximum head [m]
50
Impeller material
noryl
Vessel volume [l]
60
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
9
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
3,5
Delivery port ["]
1
Start pressure [bar]
2,1
Pump design
horizontal
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
4,50
Power output - P2 [kW]
0,65
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
60
Maximum head [m]
50
Impeller material
noryl
Vessel volume [l]
80
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
9
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
3,5
Delivery port ["]
1
Start pressure [bar]
2,1
Pump design
horizontal
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
4,50
Power output - P2 [kW]
0,65
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
60
Maximum head [m]
50
Impeller material
noryl
Vessel volume [l]
110
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
9
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
3,5
Delivery port ["]
1
Start pressure [bar]
2,1
Pump design
horizontal
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
7
Power output - P2 [kW]
1,10
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
75
Maximum head [m]
57,50
Impeller material
brass
Vessel volume [l]
60
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
5/4
Maximum suction lift [m]
9
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
4,2
Delivery port ["]
1
Start pressure [bar]
2,8
Pump design
horizontal
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
7
Power output - P2 [kW]
1,10
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
75
Maximum head [m]
57,50
Impeller material
brass
Vessel volume [l]
80
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
5/4
Maximum suction lift [m]
9
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
4,2
Delivery port ["]
1
Start pressure [bar]
2,8
Pump design
horizontal
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
7
Power output - P2 [kW]
1,10
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
75
Maximum head [m]
57,50
Impeller material
brass
Vessel volume [l]
110
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
5/4
Maximum suction lift [m]
9
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
4,2
Delivery port ["]
1
Start pressure [bar]
2,8
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
9,20
Power output - P2 [kW]
1,50
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
100
Maximum head [m]
58
Impeller material
noryl
Vessel volume [l]
100
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
5/4
Maximum suction lift [m]
7,50
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
4,6
Delivery port ["]
1
Start pressure [bar]
3,3
You are viewing this variant
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
9,20
Power output - P2 [kW]
1,50
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
100
Maximum head [m]
58
Impeller material
noryl
Vessel volume [l]
60
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
5/4
Maximum suction lift [m]
7,50
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
4,6
Delivery port ["]
1
Start pressure [bar]
3,3
Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
9,20
Power output - P2 [kW]
1,50
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
100
Maximum head [m]
58
Impeller material
noryl
Vessel volume [l]
80
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
5/4
Maximum suction lift [m]
7,50
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
4,6
Delivery port ["]
1
Start pressure [bar]
3,3

Technical Specifications

Drinking water certificate
YES
Automatic thermal protection
YES
Maximum current [A]
9,20
Power output - P2 [kW]
1,50
Capacitor
integrated
Construction
with expansion vessel
Maximum flow [l/min]
100
Maximum head [m]
58
Impeller material
noryl
Vessel volume [l]
100
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
5/4
Maximum suction lift [m]
7,50
Protection [IP]
54
Off switch
NO
Input voltage [V]
230
Stop pressure [bar]
4,6
Delivery port ["]
1
Start pressure [bar]
3,3

{9503C5C0-599E-4D74-9530-64669EDC6C10}

{74F69362-9499-4561-9BCD-9B728A39DDB8}
Calpeda S.p.A.
Via Roggia di Mezzo 39, 36050 Montorso Vicentino, IT
{13991AA5-D921-4185-9F6C-629838AEA0E6} [email protected]