Calpeda MXV 25-3xx vertical IN-LINE multi-stage pump in stainless steel INOX

Calpeda MXV 25-3xx vertical IN-LINE multi-stage pump in stainless steel INOX

Vertical Multi-Stage In-Line Pumps See more

Technical Specifications

Pump design
vertical,
Drinking water certificate
YES,
Automatic thermal protection
NO,
Maximum current [A]
2.30 - 6.60

Show all Tech Specs

from 1,211.25 VAT included

Choose variant

Register your business and get the benefits of a user account. %

Brand:
CALPEDA
Category:
Vertical surface pumps
Product No.:
MAS001200

Product variants

  • Technical Specifications
  • Product No.
  • Pump design
  • Drinking water certificate
  • Automatic thermal protection
  • Maximum current [A]
  • Power output - P2 [kW]
  • Capacitor
  • Construction
  • Maximum flow [l/min]
  • Maximum head [m]
  • Impeller material
  • Dry run protection
  • Speed ​​control
  • Suction port ["]
  • Maximum suction lift [m]
  • Protection [IP]
  • Off switch
  • Input voltage [V]
  • Delivery port ["]
  • Availability
  • Price

next

Variant Product No.

Availability

Price (VAT incl.)

Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
2.30
Power output - P2 [kW]
0.75
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
44
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1
Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
2.30
Power output - P2 [kW]
0.75
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
56
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1
Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
2.70
Power output - P2 [kW]
1.10
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
68
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1
Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
2.30
Power output - P2 [kW]
1.10
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
79.50
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1
Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
4.30
Power output - P2 [kW]
1.50
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
91
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1
Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
4.30
Power output - P2 [kW]
1.50
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
114
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1
Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
5.30
Power output - P2 [kW]
2.20
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
136
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1
Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
5.30
Power output - P2 [kW]
2.20
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
159
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1

Product No.: ZB00064434 Sale group: CECP EAN: 8030485682127 Manuf. No.: 52A18211000

2,288.96 €

Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
6.60
Power output - P2 [kW]
3
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
205
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1

Product No.: ZB00064436 Sale group: CECP EAN: 8030485672296 Manuf. No.: 52A20211000

2,424.55 €

Pump design
vertical
Drinking water certificate
YES
Automatic thermal protection
NO
Maximum current [A]
6.60
Power output - P2 [kW]
3
Capacitor
NO
Construction
multi-stage
Maximum flow [l/min]
75
Maximum head [m]
228
Impeller material
stainless steel
Dry run protection
NO
Speed ​​control
NO
Suction port ["]
1
Maximum suction lift [m]
8
Protection [IP]
55
Off switch
NO
Input voltage [V]
3x400
Delivery port ["]
1

Product description

Construction


Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line).
Corrosion-resistant bearing sleeves lubricated by the pumped liquid.
A pump with thrust bearing and sleeve coupling for use of any standard motor with IM V1 construction.

Applications


- For water supply systems.
- For clean non-explosive liquids, without solid, filamentary or abrasive matter (with adaptation of sealing materials on request).
- A universal pump for civil and industrial use, for pressure-boosting systems, fire-extinguishing systems, high-pressure washing plants, irrigation, agricultural uses and sport installations.

Technical Specifications

Pump design
vertical,
Drinking water certificate
YES,
Automatic thermal protection
NO,
Maximum current [A]
2.30 - 6.60
Power output - P2 [kW]
0.75 - 3
Capacitor
NO,
Construction
multi-stage,
Maximum flow [l/min]
75
Maximum head [m]
44 - 228
Impeller material
stainless steel,
Dry run protection
NO,
Speed ​​control
NO,
Suction port ["]
1,
Maximum suction lift [m]
8
Protection [IP]
55,
Off switch
NO,
Input voltage [V]
3x400,
Delivery port ["]
1,

{9503C5C0-599E-4D74-9530-64669EDC6C10}

{74F69362-9499-4561-9BCD-9B728A39DDB8}
Calpeda S.p.A.
Via Roggia di Mezzo 39, 36050 Montorso Vicentino, IT
{13991AA5-D921-4185-9F6C-629838AEA0E6} [email protected]